The term ‘ground gas’ refers to gases such as carbon dioxide and methane, which are generated within the ground and/or within landfills, commonly from the breakdown of vegetative matter. Ref The HS2 London-West Midlands Environmental Statement, Glossary of terms and list of abbreviations, DETR 2013.
Approved document C, Site preparation and resistance to contaminants and moisture, suggests that ‘methane and other gases’ includes hazardous soil gases (other than radon, which is dealt with separately), which originate from waste deposited in landfill or are generated naturally.
They may include gases such as methane, carbon dioxide, volatile organic compounds (VOCs) and nitrogen which can migrate through the subsoil and through cracks and fissures into buildings, where if they build up to hazardous levels, cause harm to health or compromise safety:
- Methane is an explosive and asphyxiating gas.
- Carbon dioxide is toxic.
- VOCs are flammable and toxic and can have an unpleasant odour.
They may be apparent as:
- Landfill gas, produced by the action of micro-organisms on biodegradable waste materials, including; methane, carbon dioxide and small quantities of VOCs.
- Elevated levels of carbon dioxide and nitrogen, occurring naturally in coal-mining areas
- Methane and carbon dioxide occurring in organic rich soils and sediments such as peat and river silts.
- VOCs occurring as a result of petrol, oil or solvent spillages.
The assessment of the risk from ground gases should adopt a tiered approach. A preliminary risk assessment should be undertaken, and depending on the outcome, either a generic quantitative risk assessment (GQRA) or detailed quantitative risk assessment (DQRA), or both, may be necessary.
Where risks are unacceptable then these need to be managed through appropriate building remedial measures or site-wide gas control measures, such as the removal of the gas generating material or 'covering' (placing one or more layers of materials over the site) together and the use of gas extraction systems.
Control measures for dwellings may include gas resistant barriers above an extraction or ventilation layer from which gases can be passively dispersed and vented to the atmosphere.
Control measures for non-domestic buildings, which may have a larger footprint, may require mechanical dispersal and ventilation systems, monitoring and alarms. These systems will require ongoing maintenance and calibration.
[edit] Related articles on Designing Buildings
- Brownfield land.
- Building on fill.
- Contaminated land.
- Cover systems for land regeneration - thickness of cover systems for contaminated land (BR465).
- Deleterious materials.
- Designing to reduce the chemical, biological and radiological vulnerability of new buildings (IP 7/15).
- Ground conditions.
- Landfill tax.
- Methane.
- Natural gas.
- Pollution.
- Pre construction information.
- Radon.
- Radon: Guidance on protective measures for new buildings BR 211.
- Radon protection for new domestic extensions and conservatories with solid concrete ground floors (GG 73 revised).
- Radon protection for new large buildings GG 75.
- Radon protection for new dwellings GG 74.
- Radon solutions in older homes GR 38.
- Site appraisal.
- Site information.
- Solid and liquid contaminants risk assessments.
- Synthetic methane.
Featured articles and news
Do you take the lead in a circular construction economy?
Help us develop and expand this wiki as a resource for academia and industry alike.
Warm Homes Plan Workforce Taskforce
Risks of undermining UK’s energy transition due to lack of electrotechnical industry representation, says ECA.
Cost Optimal Domestic Electrification CODE
Modelling retrofits only on costs that directly impact the consumer: upfront cost of equipment, energy costs and maintenance costs.
The Warm Homes Plan details released
What's new and what is not, with industry reactions.
Could AI and VR cause an increase the value of heritage?
The Orange book: 2026 Amendment 4 to BS 7671:2018
ECA welcomes IET and BSI content sign off.
How neural technologies could transform the design future
Enhancing legacy parametric engines, offering novel ways to explore solutions and generate geometry.
Key AI related terms to be aware of
With explanations from the UK government and other bodies.
From QS to further education teacher
Applying real world skills with the next generation.
A guide on how children can use LEGO to mirror real engineering processes.
Data infrastructure for next-generation materials science
Research Data Express to automate data processing and create AI-ready datasets for materials research.
Wired for the Future with ECA; powering skills and progress
ECA South Wales Business Day 2025, a day to remember.
AI for the conservation professional
A level of sophistication previously reserved for science fiction.
Biomass harvested in cycles of less than ten years.
An interview with the new CIAT President
Usman Yaqub BSc (Hons) PCIAT MFPWS.
Cost benefit model report of building safety regime in Wales
Proposed policy option costs for design and construction stage of the new building safety regime in Wales.
Do you receive our free biweekly newsletter?
If not you can sign up to receive it in your mailbox here.